MODEL 4650 HOT WATER CONTROL VALVE VALVE SPECIFICATIONS VALVE MATERIAL LEAD-FREE BRASS* W FRONT WITHOUT COVER INLET/OUTLET 3/4, 1 OR 1-1/4 BACK WITHOUT COVER W CYCLES 7 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 20 GPM PEAK (25 PSI DROP) 26 GPM CV (FLOW AT 1 PSI DROP) 5.2 MAX. BACKWASH (25 PSI DROP) 7 GPM REGENERATION PRODUCT FEATURES DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES BRINE FILL ONLY DESIGNED WITH DOUBLE BACKWASH TIME AVAILABLE 180 MINUTES HOT WATER CAPABILITY DIMENSIONS COMBINES RUGGED, LEAD-FREE BRASS BODY WITH TIME-TESTED DISTRIBUTOR PILOT 1.05 PIPE O...
COMMERCIAL CONTROLS THAT GROW YOUR BUSINESS AT FLECK, DECADES OF ENGINEERING AND MANUFACTURING EXPERTISE HAVE EARNED US A WORLDWIDE REPUTATION FOR QUALITY. QUALITY THAT TRANSLATES DIRECTLY INTO SOLID COMMERCIAL SUCCESS. FOR MORE THAN 50 YEARS WE'VE LED THE WAY, GENERATING NEW IDEAS THAT IGNITE SALES. OUR POSITION IN THE INDUSTRY AS INNOVATORS IS DOCUMENTED BY MULTIPLE PATENTS, NUMEROUS NEW PRODUCT INTRODUCTIONS AND OUR UNIVERSITY OF WISCONSIN COMMITMENT TO ONGOING PRODUCT LOCATION: MADISON, WISCONSIN VALVE: 2900 DUPLEX DEVELOPMENT. NOT TO MENTION THE FOLLOWING PRESTIGIOUS INSTALLATIONS: HE...
MODEL 1500 .75 RESIDENTIAL CONTROL VALVE W FRONT WITHOUT COVER VALVE SPECIFICATIONS MANUAL CONTROL OPTION VALVE MATERIAL LEAD-FREE BRASS* W INLET/OUTLET 3/4 NPTF CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 17 GPM PEAK (25 PSI DROP) 22 GPM CV (FLOW AT 1 PSI DROP) 4.8 MAX. BACKWASH (25 PSI DROP) 14 GPM REGENERATION DOWNFLOW/UPFLOW DOWNFLOW ONLY PRODUCT FEATURES ADJUSTABLE CYCLES YES TIME AVAILABLE 164 MINUTES FULLY ADJUSTABLE 5-CYCLE CONTROL DELIVERS CONTROLLED UPFLOW BACKWASH, DOWNFLOW BRINING AND SLOW RINSE, RAPID RINSE, METER INFORMATION BRINE REFILL AND DOWN...
MODEL 1500 .75 RESIDENTIAL CONTROL VALVE W FRONT WITHOUT COVER VALVE SPECIFICATIONS MANUAL CONTROL OPTION VALVE MATERIAL LEAD-FREE BRASS* W INLET/OUTLET 3/4 NPTF CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 17 GPM PEAK (25 PSI DROP) 22 GPM CV (FLOW AT 1 PSI DROP) 4.8 MAX. BACKWASH (25 PSI DROP) 14 GPM REGENERATION DOWNFLOW/UPFLOW DOWNFLOW ONLY PRODUCT FEATURES ADJUSTABLE CYCLES YES TIME AVAILABLE 164 MINUTES FULLY ADJUSTABLE 5-CYCLE CONTROL DELIVERS CONTROLLED UPFLOW BACKWASH, DOWNFLOW BRINING AND SLOW RINSE, RAPID RINSE, METER INFORMATION BRINE REFILL AND DOWN...
MODEL 9000 RESIDENTIAL TWIN TANK CONTROL VALVE VALVE SPECIFICATIONS VALVE MATERIAL LEAD-FREE BRASS** INLET/OUTLET 3/4, 1 OR 1-1/4 W FRONT WITHOUT COVER CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE FLOW RATE (50 PSI INLET) 1 METER 3/4 METER CONTINUOUS (15 PSI DROP) 21 GPM 18 GPM PEAK (25 PSI DROP) 28 GPM 24 GPM CV (FLOW AT 1 PSI DROP) 5.1 4.8 MAX. BACKWASH (25 PSI DROP) 8.5 GPM 8.5 GPM REGENERATION W BACK WITHOUT COVER DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES YES TIME AVAILABLE 164 OR 82 MINUTES PRODUCT FEATURES METER INFORMATION FULLY ADJUSTABLE 5-CYCLE CONTROL DELIVERS CONTROLL...
MODEL 9000 RESIDENTIAL TWIN TANK CONTROL VALVE VALVE SPECIFICATIONS VALVE MATERIAL LEAD-FREE BRASS** INLET/OUTLET 3/4, 1 OR 1-1/4 W FRONT WITHOUT COVER CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE FLOW RATE (50 PSI INLET) 1 METER 3/4 METER CONTINUOUS (15 PSI DROP) 21 GPM 18 GPM PEAK (25 PSI DROP) 28 GPM 24 GPM CV (FLOW AT 1 PSI DROP) 5.1 4.8 MAX. BACKWASH (25 PSI DROP) 8.5 GPM 8.5 GPM REGENERATION W BACK WITHOUT COVER DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES YES TIME AVAILABLE 164 OR 82 MINUTES PRODUCT FEATURES METER INFORMATION FULLY ADJUSTABLE 5-CYCLE CONTROL DELIVERS CONTROLL...
FLECK SE (SIMPLE ELECTRONICS) CONTROLS SIMPLE ELECTRONICS FROM FLECK PROVIDE EASY, STEP-BY-STEP PROGRAMMING AT THE TOUCH OF A BUTTON. SETUP IN FIVE SIMPLE STEPS THE SAME SE CONTROL DRIVES SIX DIFFERENT FLECK VALVES, 1. TO SET THE TIME OF DAY SIMPLY PUSH THE UP SAVING YOU TIME IN INSTALLATION, SERVICE AND TRAINING. UNLIKE OTHER ELECTRONIC VALVES, THE SE CONTROL PERFORMS WITHOUT OR DOWN BUTTONS. SWITCHING OUT CAMS OR FUMBLING WITH JUMPERS, PINS AND 2. GET INTO THE PROGRAMMING MODE BY PRESSING CRYPTIC CALCULATIONS. THE UP AND DOWN BUTTONS TOGETHER A BRIGHT LED DISPLAYS THE TIME OF DAY, SOFT W...
MODEL 5600 MECHANICAL CONTROL VALVE VALVE SPECIFICATIONS VALVE MATERIAL NORYL®* INLET/OUTLET 3/4, 1, 1-1/4 NPTF CYCLES 7 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 20 GPM PEAK (25 PSI DROP) 26 GPM W BACK CV (FLOW AT 1 PSI DROP) 5.0 OF VALVE WITHOUT MAX. BACKWASH (25 PSI DROP) 7 GPM COVER REGENERATION DOWNFLOW/UPFLOW BOTH PRODUCT FEATURES ADJUSTABLE CYCLES BRINE FLOW ONLY TIME AVAILABLE 180 MINUTES SIMPLE MECHANICAL DESIGN IS EASY TO UNDERSTAND METER INFORMATION TWO VALVE BODY DESIGNS: ONE FOR DOWNFLOW REGENERATION METER ACCURACY RANGE .25 - 15 GPM +/- 5% AND ONE FOR U...
MODEL 5600 MECHANICAL CONTROL VALVE VALVE SPECIFICATIONS VALVE MATERIAL NORYL®* INLET/OUTLET 3/4, 1, 1-1/4 NPTF CYCLES 7 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 20 GPM PEAK (25 PSI DROP) 26 GPM W BACK CV (FLOW AT 1 PSI DROP) 5.0 OF VALVE WITHOUT MAX. BACKWASH (25 PSI DROP) 7 GPM COVER REGENERATION DOWNFLOW/UPFLOW BOTH PRODUCT FEATURES ADJUSTABLE CYCLES BRINE FLOW ONLY TIME AVAILABLE 180 MINUTES SIMPLE MECHANICAL DESIGN IS EASY TO UNDERSTAND METER INFORMATION TWO VALVE BODY DESIGNS: ONE FOR DOWNFLOW REGENERATION METER ACCURACY RANGE .25 - 15 GPM +/- 5% AND ONE FOR U...
MODEL 2510 CONTROL VALVE W FRONT WITHOUT COVER VALVE SPECIFICATIONS BACK VALVE MATERIAL FIBER REINFORCED POLYMER W INLET/OUTLET 3/4, 1 OR 1-1/4 CYCLES 5 FLOW RATES (50 PSI INLET) - VALVE ALONE CONTINUOUS (15 PSI DROP) 19 GPM PEAK (25 PSI DROP) 24 GPM CV (FLOW AT 1 PSI DROP) 4.8 MAX. BACKWASH (25 PSI DROP) 17 GPM REGENERATION PRODUCT FEATURES DOWNFLOW/UPFLOW DOWNFLOW ONLY ADJUSTABLE CYCLES YES FULLY ADJUSTABLE 5-CYCLE TOP MOUNT CONTROL DELIVERS TIME AVAILABLE ELECTROMECHANICAL: 164 MINUTES CONTROLLED UPFLOW BACKWASH, DOWNFLOW BRINING AND SLOW SE: 0 - 99 MINUTES RINSE, RAPID RINSE, BRINE REF...